Solution Informationhelp
Enzyme: SUMO-activating enzyme subunit 1
inhibitor: BDBM47952
substrate: n/a
 
Solution Type: Aqueous
pH at Preparation: n/a
Temp. Prep.: n/a
Comments: Assay materials: 1) E1, E2, GST-SUMO and His6-RanGap-1 proteins were obtained from the assay provider's laboratory. 2) Assay Buffer: 50mM Tris-HCl pH 7.4, 0.3mM DTT, 10 mM MgCl2, 0.005% Tween-20 3) Anti-GST XL665 and Anti-His Europium-labeled antibodies were purchased from Cis-Bio (Cat # 61GSTXLB and 61HISXLB) 4) Corning 1536-well, white plates (Cat #3725) uHTS Procedure 1) Dispense 2ul of assay buffer into columns 1 and 2, and 2ul of Mixture 1, containing 37.5 nM E1 and 100 nM His-RanGap-1 in the assay buffer, into columns 3-48 of the 1536-well assay plate. 2) Using a HighRes biosolutions pintool dispense 70nl of 2mM compounds in DMSO to columns 5-48 3) Dispense 70nl of DMSO to columns 1-4. 4) Using Thermo Scientific MultiDrop Combi, dispense 2 uL of Mixture 2, containing 20 mM ATP, 12.5 nM E2 and 30 nM GST-SUMO in assay buffer, to all wells. 5) Incubate for 30 min. at room temperature. 6) Add 1ul of 500 mM KF 7) Read plate on a BMG Labtech PheraStar in a Homogeneous Time-Reso
 
 